User's Manual
OPERATION 5
51
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
ECV
Format: U1
Reader parameter definition.
The values are displayed as decimal values!
Parameters
:
Parameter 0: Gateway ID
The gateway ID is a part of the device ID. The LDN reader works
simultaneously as a gateway and a reader (CIDRW with integrated
head).
It is the “lower message ID” in the message header.
00 .. 255
Default: Last two characters of hex serial number
The default gateway ID corresponds to Parameter 8. (Lowbyte
TargetID)
Parameter 1: Baudrate
Data transmission rate to the SECS-Host
3: 300 Baud
6: 600 Baud
12: 1200 Baud
24: 2400 Baud
48: 4800 Baud
96: 9600 Baud
192: 19200 Baud
200: 38400 Baud
201: 57600 Baud
202: 115200 Baud
Default :(192) 19200 Baud (see accompanying letter of the reader)