User's Manual
5 OPERATION
50
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
DATASEG
Format:A[2]
Description: Used to identify the data requested.
The DATASEG corresponds to the page number (PAGEID) of
multipage, read/only and read/write transponders
“00”: First page of any type of transponder or first page of
the DATA area in case of a multipage transponder.
Multipage-transponder (page 1 to page 17) :
Start the reading or writing on the following page of a multipage
transponder:
“01”: page 1 “81”: Locked page 1
... ...
“11”: page 17 “91”: Locked page 17
Read/only transponder: “F0”: Read only the one page
Read/write transponder: “F1”: Read or write only the one page
Where used: S18F5, S18F7
EAC
Format: B[1]
Acknowledge code for new reader constant
0: Parameter was set successfully
1: Parameter could not be set
Where used: S2F16
ECID
Format: U1
Parameter number of reader (see data item ECV)
Where used: S2F13, S2F15