User's Manual

OPERATION 5
45
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
10: Locked page could not be written
11: Reserved
12: Incorrect type of transponder
13: External read or write failed because the sensor is not covered
14: Reserved
15: Reserved
16: Reserved
Where used: S5F1
ALTX
Format: A[max40]
Alarm Text
The length of the alarm text is 0 to 40 signs.
According to the reader version, state information about the sensor or
sensors is also transmitted during a reader failure message.
The information should be interpreted as follows:
ALTX[0] Initiator of a failure message
“0”: Sensor 0
“1”: Sensor 1 (not available)
“F”: Cannot be assigned
ALTX[1] State of sensor 0
“0”: Sensor not occupied
“1”: Sensor is occupied
“E”: Sensor state is not available
“F”: Sensor not defined
ALTX[2] State of sensor 1
“0”: Sensor not occupied
“1”: Sensor is occupied
“E”: Sensor state is not available
“F”: Sensor not defined