User's Manual
OPERATION 5
41
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
Data item examples:
5.4.3 Message set
The SECSII-message-set used by the LDN reader consists of six
different stream types.
Stream 1: (Equipment status
)
- S1F1 and S1F2 Are you there request
- S1F15 and S1F16 Request offline
- S1F17 and S1F18 Request online
Stream 2: (Equipment control)
- S2F13 and S2F14 Equipment constant request
- S2F15 and S2F16 New equipment constant request
- S2F19 and S2F20 Reset send
Stream 3: (Material status)
- S3F5 and S3F6 Cassette found send
- S3F7 and S3F8 Cassette lost send
- S3F11 and S3F12 Read MID at I/O port
- S3F13 and S3F14 Return read MID
- S3F65 and S3F66 Write MID at I/O port
- S3F67 and S3F68 Return write success
- S3F73 and S3F74 Lock MID at I/O port
- S3F75 and S3F76 Return lock success
Meaning Format Length
1- Byte
Integer
65 01 xx
4- Byte
Integer
71 04 MSB ... ... LSB
ASCII 41 06 1.chr 2.chr 3.chr 4.chr 5.chr 6.chr
zero-length xx 00
List Data Item 01 03 1. element 2. element 3. element