User's Manual

OPERATION 5
111
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
41 04 49 44 4C 45 Æ HeadStatus “IDLE”
In : Checksum ( 08 68)
Out: ACK ( 06 )
Reset is an optional service used to reinitialize the reader. If
reader parameter 9 is unequal to 0x00, the reset causes a S1F1
“Are you there” message from the reader.
The reader detects a wrong TARGETID
Host to Reader: S18F5
Out: ENQ ( 05 )
In : EOT ( 04 )
Out: Length Byte ( 1A )
Out: Header ( 01 FF 92 05 80 01 00 00 00 40 )
Out: Data
01 03
41 04 30 30 30 30 Æ TARGETID “0000”
41 02 30 31 Æ DATASEG “01”
A9 02 00 08 Æ DATALENGTH 0x08
Out: Checksum ( B8 02 )
In : ACK ( 06 )
Reader to Host: S18F6
In : ENQ ( 05 )
Out: EOT ( 04 )
In : Length Byte ( 18 )
In : Header ( 81 FF 12 06 80 01 00 00 00 40 )
In : Data
01 03
41 04 31 32 33 34 Æ TARGETID “1234”
41 02 43 45 Æ SSACK “CE”
41 00 Æ DATA ““
In : Checksum ( 04 78 )
Out: ACK ( 06 )