User's Manual
OPERATION 5
109
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
If the reader remains in the IDLE state, the command fails and the
reader answers with SSACK “EE” (execute error).
Host changes the reader state from IDLE to MANT with S18F13
Host to Reader: S18F13
Out: ENQ ( 05 )
In : EOT ( 04 )
Out: Length Byte ( 25 )
Out: Header ( 01 FF 92 0D 80 01 00 00 00 67 )
Out: Data
01 03
41 04 31 32 33 34 Æ TARGETID “1234”
41 0B 43 68 61 6E 67 65 53 74 61 74 65
Æ SSCMD “ChangeState”
01 01
41 02 4D 54 Æ CPVAL1 “MT”
Out: Checksum ( 13 02 )
In : ACK ( 06 )
Reader to Host: S18F14
In : ENQ ( 05 )
Out: EOT ( 04 )
In : Length Byte ( 2D )
In : Header ( 81 FF 12 0E 80 01 00 00 00 67 )
In : Data
01 03
41 04 31 32 33 34 Æ TARGETID “1234”
41 02 4E 4F Æ SSACK “NO”
01 01
01 04 Æ STATUS <L4>
41 02 4E 45 Æ PMInformation “NE”
41 01 30 Æ Alarmstatus “0”
41 04 4D 41 4E 54 Æ OperationalStatus “MANT”
41 04 4E 4F 4F 50 Æ HeadStatus “NOOP”
In : Checksum ( 08 C0 )
Out: ACK ( 06 )