User's Manual

5 OPERATION
108
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
Host writes material ID of a multipage transponder with S18F11
Host to Reader: S18F11
Out: ENQ ( 05 )
In : EOT ( 04 )
Out: Length Byte ( 1C )
Out: Header ( 01 FF 92 0B 80 01 00 00 00 66 )
Out: Data
01 02
41 04 31 32 33 34 Æ TARGETID “1234”
41 08 4E 72 2E 30 30 41 42 43 Æ MID “Nr.00ABC”
Out: Checksum ( F3 02 )
In : ACK ( 06 )
Reader to Host: S18F12
In : ENQ ( 05 )
Out: EOT ( 04 )
In : Length Byte ( 2D )
In : Header ( 81 FF 12 0C 80 01 00 00 00 66 )
In : Data
01 03
41 04 31 32 33 34 Æ TARGETID “1234”
41 02 4E 4F Æ SSACK “NO”
01 01
01 04 Æ STATUS <L4>
41 02 4E 45 Æ PMInformation “NE”
41 01 30 Æ Alarmstatus “0”
41 04 4D 41 4E 54 Æ OperationalStatus “MANT
41 04 4E 4F 4F 50 Æ HeadStatus “NOOP”
In : Checksum ( 08 BD )
Out: ACK ( 06 )
The host wants to write a new material ID to any transponder. The
reader confirms the success of the write MID command with SSACK
“NO”. Note: the material ID can be changed only if the reader is in the
maintenance state. (MANT)