User's Manual
5 OPERATION
106
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
Host writes data on page 10 with S18F7
Host to Reader: S18F7
Out: ENQ ( 05 )
In : EOT ( 04 )
Out: Length Byte ( 24 )
Out: Header ( 01 FF 92 07 80 01 00 00 00 18 )
Out: Data
01 04
41 04 31 32 33 34 Æ TARGETID “1234”
41 02 30 41 Æ DATASEG “0A”
A9 02 00 08 Æ DATALENGTH 0x08
41 08 41 42 43 44 45 46 47 48 Æ DATA “ABCDEFGH”
Out: Checksum ( 1A 02 )
In : ACK ( 06 )
Reader to Host: S18F8
In : ENQ ( 05 )
Out: EOT ( 04 )
In : Length Byte ( 2D )
In : Header ( 81 FF 12 08 80 01 00 00 00 18 )
In : Data
01 03
41 04 31 32 33 34 Æ TARGETID “1234”
41 02 4E 4F Æ SSACK “NO”
01 01
01 04 Æ STATUS <L4>
41 02 4E 45 Æ PMInformation “NE”
41 01 30 Æ Alarmstatus “0”
41 04 49 44 4C 45 Æ OperationalStatus “IDLE”
41 04 49 44 4C 45 Æ HeadStatus “IDLE”
In : Checksum ( 08 3B )
Out: ACK ( 06 )
The host writes the ASCII string “ABCDEFGH” to page 10. The reader
confirms the write command with SSACK “NO” in the S18F8
message.