User's Manual
Table Of Contents
- Product Manual RFID Reader LF40C THR
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Normal operating mode
- 7.3 Setup mode
- 7.3.1 Parameter
- Parameter 0 (0x00)
- Parameter 6 (0x06)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 39 (0x27)
- Parameter 80 (0x50)
- Parameter 81 (0x51)
- Parameter 82 (0x52)
- Parameter 83 (0x53)
- Parameter 85 (0x55)
- Parameter 86 (0x56)
- Parameter 97 (0x61)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.3.1 Parameter
- 7.4 Status diagram as overview
- 7.5 Flow chart
- 7.6 ASCII values for setup
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- Index
Product Manual - RFID Reader LF40C THR 37
Chapter 7
Operation
Parameter 85
(0x55)
Language
This parameter defines the keyboard layout.
Values:
English - 00 – English (QWERTY)
German - 01 – German (QWERTZ)
French - 02 – French (AZERTY)
Default: German (01)
Parameter 86
(0x56)
Buzzer
Activates or deactivates the internal buzzer (sound signal) of the reader.
Values:
off - 00 – buzzer off
on - 01 – buzzer on
Default: on (01)
Parameter 97
(0x61)
ShowNoneVisibleASCII
This parameter determines whether a non-visible ASCII character is displayed on
the screen by a , or is not displayed.
Values:
off - 00 – do not display
on - 01 – display
Default: off (00)
Parameter 98
(0x62)
NumPrefix
Defines the number of prefix characters that are to be added in front of the read
result. This parameter is only valid in combination with parameter 82.
Values:
00…. 10 - number of prefixes
Default: 00 (no prefix)
Parameter 99
(0x63)
NumSuffix
Defines the number of suffix characters that are to be added after the read result.
This parameter is only valid in combination with parameter 83.
Values:
00…. 10 - number of suffixes
Default: 00 (no suffix)