User's Manual
Table Of Contents
- Product Manual RFID Reader LF40C THR
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Normal operating mode
- 7.3 Setup mode
- 7.3.1 Parameter
- Parameter 0 (0x00)
- Parameter 6 (0x06)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 39 (0x27)
- Parameter 80 (0x50)
- Parameter 81 (0x51)
- Parameter 82 (0x52)
- Parameter 83 (0x53)
- Parameter 85 (0x55)
- Parameter 86 (0x56)
- Parameter 97 (0x61)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.3.1 Parameter
- 7.4 Status diagram as overview
- 7.5 Flow chart
- 7.6 ASCII values for setup
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- Index
Product Manual - RFID Reader LF40C THR 34
Chapter 7
Operation
Parameter 32
(0x20)
ShowTagType
The transponder type can also be displayed. For this purpose, a number for the
transponder type is displayed in front of the actual transponder data. This
behavior can be activated or deactivated.
Values:
on - transponder type is displayed
off - transponder type is not displayed
Default: off
The transponder types are displayed by the following values:
01 - Read Only Transponder
02 - Read/Write Transponder
03 - Multipage Transponder
Parameter 33
(0x21)
ReadPage
This parameter determines the start position of a read operation on a multipage
transponder.
Values:
0x01 .. 0x11 - page 1 to 17
Default: 0x01 (standard value for scanning)
When the value is 0, the different transponder types are read as follows:
Multipage transponder - only page 1 is read (8 bytes)
Read Only - entire transponder is read (8 bytes)
Read/Write - entire transponder is read (8 bytes)
The transponder types Read Only and Read/Write can only be read when the
value is 0.
Parameter 34
(0x22)
ReadLength
This parameter defines the length of the data (intervals of 8 bytes) that are to be
read during a read operation.
The displayed value adjusts to the value of the parameter ReadPage. This means
that if the read operation starts from page 1, a maximum of 136 (= 17 pages x 8)
bytes can be read. However, if the read operation starts from page 2, then a
maximum of only 128 (16 pages x 8) bytes can be read.
Values:
0x08…0x88 - read (n*8) bytes, with n = 1..17 (page)
Default: 08 (read 8 bytes)