User's Manual
Table Of Contents
- Product Manual RFID Reader LF40C THR
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Normal operating mode
- 7.3 Setup mode
- 7.3.1 Parameter
- Parameter 0 (0x00)
- Parameter 6 (0x06)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 39 (0x27)
- Parameter 80 (0x50)
- Parameter 81 (0x51)
- Parameter 82 (0x52)
- Parameter 83 (0x53)
- Parameter 85 (0x55)
- Parameter 86 (0x56)
- Parameter 97 (0x61)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.3.1 Parameter
- 7.4 Status diagram as overview
- 7.5 Flow chart
- 7.6 ASCII values for setup
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- Index
Product Manual - RFID Reader LF40C THR 33
Chapter 7
Operation
Parameter 0
(0x00)
Customer
Defines whether the reader is configured with the standard settings of the
parameters or with customer-specific settings.
Values:
Standard = 00
Customer mode 1 = 01
Customer mode 2 = 02
Default: 00
If the reader is in customer mode 1, the following parameters differ from the
standard settings:
Parameter 0x21 00
Parameter 0x50 add Tab
Parameter 0x55 English
If the reader is in customer mode 2, the following parameters differ from the
standard settings:
Parameter 0x21 00
Parameter 0x52 19
Parameter 0x55 English
Furthermore, the setup menu is blocked as soon as the reader has entered
customer mode 1. To unblock the setup menu, press the following button
combination: Press and hold the set button while pressing the read button three
times. Then stop pressing the set button. The parameter menu is displayed again.
Parameter 6
(0x06)
Retry
Determines the internal repetitions of the read operation if the read operation has
not been successful.
Values:
00… 1F (0 to 31)
Default: 03
97 0x61 ShowNoneVisibleASCII
98 0x62 NumPrefix
99 0x63 NumSuffix
No.
(dec.)
No.
(hex)
Parameter name