User's Manual

OPERATION 5
71
HF80 Transponder Reader – HSMS, Release 1.3
SSCMD
Format: A[max18]
Description: Indicates an action to be performed by the subsystem.
Used to differentiate between the different subsystem commands
indicated.
“ChangeState” Change state
“GetStatus” Get state
“PerformDiagnostics” Perform diagnostics
“Reset” Reset CIDRW
Where used: S18F13
SSTATE
Format: A[max 3]
Description: Provides status information of the external I/O of a
specific head.
“ON” - Sensor is occupied
“OFF” - Sensor is unoccupied
Where used: S18F71
STATE
Format: A[max 5]
Description: State of the external outputs of a specific head.
“ON” Output is ON
“OFF” Output is OFF
“FLASH” Output is flashing
“KEEP” Output remains current state
Where used: S18F77