User's Manual
5 OPERATION
70
HF80 Transponder Reader – HSMS, Release 1.3
SHEAD
Format: B[10]
Stored SECS message block header. Only the last message is stored,
which must still be confirmed by the host!
Where used: S9F9
SOFTREV
Format: A[max 6]
Software revision code.
Where used: S1F2
SSACK
Format: A[2]
Description: Result information on the status of the request
concerning the service request.
“NO” … Normal operation
Indicates the success of the requested action
“EE” … Execute error
Cannot read tag data . Cannot read ID
sequence. But equipment is normal.
“CE” … Communication error
Syntax error of message or message format or
value.
“HE” … Hardware error
ID reader/writer head fault, ID reader/writer
head is powered off.
“TE” … Tag error
Where used: S18F2, S18F4, S18F6, S18F8, S18F10, S18F12, S18F14,
S18F66, S18F68, S18F70, S18F72, S18F74, S18F76,
S18F78, S18F80