User's Manual

5 OPERATION
62
HF80 Transponder Reader – HSMS, Release 1.3
Parameter 37: MID area
This parameter defines the range of the MID.
‘0’ … ‘10’ pages
Default: ‘4’ – MID area = 4 pages = 16 bytes (depends on
transponder type).
See also parameter 42 – 45 and 99.
Parameter 38: Test After Soft Reset
This parameter enables/disables the initial test after a software reset.
0x00 No initial test after software reset
0x01 Initial test after software reset
0x11 polling Inventory on head 1 after software reset
0x12 polling Inventory on head 2 after software reset
0x13 polling Inventory on head 3 after software reset
0x14 polling Inventory on head 4 after software reset
0x15 polling Inventory on head 5 after software reset
0x21 polling read and write on head 1 after software reset
0x22 polling read and write on head 2 after software reset
0x23 polling read and write on head 3 after software reset
0x24 polling read and write on head 4 after software reset
0x25 polling read and write on head 5 after software reset
Default: (0) No initial test after software reset