User's Manual

OPERATION 5
57
HF80 Transponder Reader – HSMS, Release 1.3
Parameter 13: Communication port
The communication with the host can be done by by HSMS (TCP/IP)
or optional by SECS1 (RS232) interface. The following options are
possible:
0x11: Host Æ Reader: HSMS
Reader Æ Host: HSMS
0x22: Host Æ Reader: SECS1
Reader Æ Host: SECS1
The setting of the DIP switch 1 affects this parameter! The
setting of the DIP switch has priority and will be stored in
the parameter after a reset.
Attention! If the reader has only one interface (TCP/IP or RS232)
the changing of parameter 13 to a value where the not
installed interface option will be activated and the DIP
switch 1 is deactivated will set the reader to a mode
where no communication with the reader is possible.
Then the parameter can not be switched back to correct
value.
default: (0x11) Ethernet
Parameter 14, 15, 17, 18 and 19 are not defined!
Parameter 16: Antenna Power Level
Defines the power level at antenna. Minimum 200mW and maximum
1000mW.
00 .. 31
default: 0x1F (highest power)