User's Manual
OPERATION 5
53
HF80 Transponder Reader – HSMS, Release 1.3
DATASEG
Format:A[2]
Description: Used to identify the data requested.
The DATASEG corresponds to the page number (PAGEID) of the ISO
15693 transponder.
“00”: First page of any type of transponder or first page of the
DATA area.
Where used: S18F5, S18F7, S18F67, S18F69
DATASEGB
Format:B[1]
Description: Used to identify the data requested.
The DATASEG corresponds to the real byte of the ISO 15693
transponder.
Empty First byte of DATA area (depends on MID settings).
Where used: S18F5, S18F7, S18F67, S18F69
EAC
Format: B[1]
Acknowledge code for new reader constant
0 … Parameter was set successfully
1 … Parameter could not be set
Where used: S2F16
ECID
Format: U1
Parameter number of reader (see data item ECV)
Where used: S2F13, S2F15