User's Manual
OPERATION 5
47
HF80 Transponder Reader – HSMS, Release 1.3
According to SEMI E99 carrier ID read/writer functional standard for
SECS-1 and SECS-2 protocol, the BROOKS reader supports the
defined stream 18 messages.
Stream 18: (Equipment status)
- S18F1 and S18F2 Read attribute request
- S18F3 and S18F4 Write attribute request
- S18F5 and S18F6 Read request
- S18F7 and S18F8 Write request
- S18F9 and S18F10 Read ID request
- S18F11 and S18F12 Write ID request
- S18F13 and S18F14 Subsystem command request
- S18F65 and S18F66 Scan Transponder
- S18F67 and S18F68 Read data request – UID
- S18F69 and S18F70 Write data request – UID
- S18F71 and S18F72 Sensor State
- S18F73 and S18F74 Read ID request –UID
- S18F75 and S18F76 Write ID request – UID
- S18F77 and S18F78 Set Output State
- S18F79 and S18F80 Get Output State
- S18F85 and S18F86 Scan and Read ID request
- S18F87 and S18F88 Read Write-Counter
- S18F89 and S18F90 Read Write-Counter with UID