User's Manual
OPERATION 5
123
HF80 Transponder Reader – HSMS, Release 1.3
S18F7 Write Data: DATASEG=<56> and DATALENGTH=<4> and
DATA[4]
< L4
< A TARGETID = '01' >
< U2 DATASEGB = 56 >
< U2 DATALENGTH = 4 >
< B DATA = 44 45 46 47 >
>
S18F8 (WDA) - write data ACK
< L3
< A TARGETID = '01' >
< A SSACK = 'NO' >
< L4 - STATUS1
< PMInformation
< A = 'NE' >
< A = '0' >
< A = 'IDLE' >
< A = 'IDLE' >
>
>
Host reads material ID of a multipage transponder with S18F9
Host to Reader: S18F9
Out: ENQ ( 05 )
In: EOT ( 04 )
Out: Length Byte ( 0E )
Out: Header ( 00 00 92 09 80 01 00 00 00 17 )
Out: Data 41 02 30 31 Æ TARGETID “01”
Out: Checksum ( D7 02 )
In: ACK ( 06 )
Reader to Host: S18F10
In: ENQ ( 05 )
Out: EOT ( 04 )
In: Length Byte ( 3D )
In: Header ( 80 00 12 0A 80 01 00 00 00 17 )
In: Data 01 04
41 02 30 31 Æ TARGETID “01”
41 02 4E 4F Æ SSACK “NO”
41 10 4D 49 44 20 30 30 30 30 30