User's Manual
OPERATION 5
65
HF5x Transponder Reader (SECS1-Protocol), Release 1.4
S1F15: REQUEST OFF_LINE (host ->reader, reply)
The reader is requested to change the communication state to offline.
The reader can only be set online again by using message S1F17 (or
reset S2F19), all other messages will be aborted by the SxF0 message!
S1F15 W. *Header Only
S1F16: OFFLINE ACKNOWLEDGE (reader -> host)
Acknowledge.
S1F16
<OFLACK>.
S1F17: REQUEST ON_LINE (host ->reader, reply)
The reader is requested to change the communication state to online.
S1F17 W. *Header Only
S1F18: ONLINE ACKNOWLEDGE (reader -> host)
Acknowledge.
S1F18
<ONLACK>.