User's Manual
OPERATION 5
57
HF5x Transponder Reader (SECS1-Protocol), Release 1.4
“CE” … Communication error
Syntax error of message or message format or
value.
“HE” … Hardware error
ID reader/writer head fault, ID reader/writer
head is powered off.
“TE” … Tag error
Where used: S18F2, S18F4, S18F6, S18F8, S18F10, S18F12, S18F14,
S18F66, S18F68, S18F70, S18F72, S18F74, S18F76,
S18F78, S18F80
SSCMD
Format: A[max18]
Description: Indicates an action to be performed by the subsystem.
Used to differentiate between the different subsystem commands
indicated.
“ChangeState” … Change state
“GetStatus” … Get state
“PerformDiagnostics” … Perform diagnostics
“Reset” … Reset CIDRW
Where used: S18F13
SSTATE
Format: A[max 3]
Description: Provides status information of the external I/O of a
specific head.
“ON” - Sensor is occupied
“OFF” - Sensor is unoccupied
Where used: S18F71