User's Manual

5 OPERATION
52
HF5x Transponder Reader (SECS1-Protocol), Release 1.4
Parameter 44: FixedMID
Defines the read, write and error behavior regarding CarrierIDLength
defined in SEMI E99-0303.
0 Dynamic CID length (to ensure compatibility with
older versions)
MID length is variable for writing to the tag.
Reading up to the first non-visible ASCII character.
1 Fixed CID length (to meet the new standard revision)
Length of MID in the tag must be the same as the
reader settings. If there is a non-visible ASCII
character within the CID field, an error occurs.
Default: 1
For software version RS2H23 and higher.
Parameter 45: MIDFormat
Defines the physical format of the MID data in the transponder
memory.
0 E99 standard format left aligned – meets the requirement
of the SEMI standard E99
1 MID format right aligned – filler byte is ASCII ‘0’ (0x30)
Reading: leading ‘0’ will displayed.
2 MID format right aligned – filler byte is ASCII ‘0’ (0x30)
Reading: leading ‘0’ will not displayed.
If parameter 45 is not ‘0’ the parameters 42, 43 and 44 are
not effective.
Default: 0
For software version RS2H23 and higher.