User's Manual
5 OPERATION
46
HF5x Transponder Reader (SECS1-Protocol), Release 1.4
Parameter 6: Retry limit RTY
Number how often a question or a message shall be repeated.
0 .. 31
Default: 3
Parameter 7: TARGETID HighByte
Highbyte of the predefined TARGETID (not changeable).
Parameter 8: TARGETID LowByte
Lowbyte of the predefined TARGETID (not changeable).
Parameter 9: Heartbeattime
The reader offers the option of generating a regular heartbeat. This
means the reader sends a S1F1 message to the host in the defined
interval.
0 … No heartbeat
1 … 255 10s (10s - 2550s)
Default: 0 no heartbeat
Parameter 10: Not defined!
Parameter 11: Reader-ID
The reader ID is a part of the device ID. In the message header, it
corresponds to the 7 LSB (last significant bits) of the “upper message
ID”.
00 .. 127
Default: 0x00
The BROOKS reader works as a gateway (CIDRW) with up to 5
integrated heads. Therefore the reader ID is predefined as 0x00. Of
course, the ID can be changed within the valid scope.
Parameter 12-19: Not defined!