User's Manual

OPERATION 5
37
HF5x Transponder Reader (SECS1-Protocol), Release 1.4
Data item examples:
5.4.3 Message set
The SECSII-message-set used by the BROOKS HF5x transponder
reader consist of six different stream types.
Stream 1: (Equipment status
)
- S1F1 and S1F2 Are you there request
- S1F15 and S1F16 Request offline
- S1F17 and S1F18 Request online
Stream 2: (Equipment control)
- S2F13 and S2F14 Equipment constant request
- S2F15 and S2F16 New equipment constant request
- S2F19 and S2F20 Reset send
Stream 9: (System errors)
- S9F1 Unrecognized device ID
- S9F3 Unrecognized stream type
- S9F5 Unrecognized function type
- S9F7 Illegal data
- S9F9 Transaction timer timeout
Meaning Format Length
1- Byte
Integer
65 01 xx
4- Byte
Integer
71 04 MSB ... ... LSB
ASCII 41 06 1.chr 2.chr 3.chr 4.chr 5.chr 6.chr
zero-length xx 00
List Data Item 01 03 1. element 2. element 3. element