User's Manual

6 SERVICE AND ERROR HANDLING
118
HF5x Transponder Reader (SECS1-Protocol), Release 1.4
6.7 Power Cut
After a power cut, the reader carries out a reset with self-test. While
the self-test is running, the status LED is ON. If the test was
successful, all LEDs, except for the power LED, are extinguished.
6.8 Software Releases
Release Date Version Description
11/27/2000 RS2V10 First version. (without membrane keyboard)
04/2003 RS2V20 New type of EEPROM.
04/2003 RS2V21
S18F67 Read Data Request with UID
S18F69 Write Data Request with UID
05/2003 RS2V22 Fixes some reset problems.
06/2003 RS2V23
Implementation of the external inputs.
New message S18F71 (Sensorstate)
New parameters for each sensor "S1State"
value = "ON" or "OFF"
In test mode all MID write and read
functions are available.
Implementation of SEMI Standard E99-
0303.
Parameter 42 CarrierIDOffset (ECID_42)
Parameter 43 CarrierIDLength (ECID_43)
Parameter 44 FixedMID (ECID_44)
Parameter 45 MIDFormat (ECID_45)
09/2003 RS2H24
S18F73 Read MID with UID
S18F75 Write MID with UID
S18F65 SCAN Transponder Request is also
available in maintenance mode (MT)
10/2003 RS2H25
Testversion for customer:
default DeviceID is 0x00
(parameter 0 + 11)
16.10.03 RS2H26
S18F77 SetOutputState
S18F79 GetOutputState
Parameter 26-30 Watchport for Sensor 1-5
MSB defines the sensor type (pos. or neg.)
(pos.: sensor occupied "ON")
(neg.: sensor occupied "OFF")
31.10.03 RS2H27
Set the reader to 100% modulation
Infineon Tags implemented
Scan and all UID messages adapted
New parameter 32 transponder type
default = Infineon Type