Product Manual 7.5 Operation of the SECS Protocol
Exceptions:
If the attribute list is empty (L,0), the following 10 attributes are returned
in the order specified bellow:
Configuration
AlarmStatus
OperationalStatus
HeadStatus
HeadID
HardwareRevisionLevel
Manufacturer
ModelNumber
SoftwareRevisionLevel
SerialNumber
If the TargetID is invalid, no statuses are sent (list of zero).
S18F3: WRITE ATTRIBUTE REQUEST (WAR) (H -> E)
This message requests the subsystem to set the value of the read/write
attributes of the component specified in the TARGETID.
S18F3 is a transactional message, i.e. either all attributes will
be set at once or none.
S18F3 ,W
L,2
<TARGETID>
L,2
<ATTRID1>
<ATTRVAL1>
L,2
<ATTRIDn>
<ATTRVALn>