User's Manual

Table Of Contents
Brooks Automation
260301 Revision A 51
ATR60LF RFID Reader CAN Bus 7 Operation
Product Manual 7.4 Attribute (ECID and SVID) Values
P - Pass
F - Failed
SENSOR_TIMEOUT Sensor delay after the trigger
Range 1 - 20
Unit 1 = 100 ms
Default: 01
SERIALNUM Serial number of the target device
Assigned at the factory and indicated on the label of the device, e.g.
1101MIS100001.
SerialNumber See SERIALNUM
SIGNALSTRENGTH
(Read only)
Read only information RF signal strength (noise level!)
SW_PARTNUMBER Software part number
SOFTREV Subsystem software revision of Gateway or reader (head)
SoftwareRevision-
Level
See SOFTREV
STATUS_ENABLE If set to Enable, Head communicates the STATUS information back to the
host.
EN = Enabled
DI = Disabled
Default: EN
TARGETID The TargetID of the device, adjustable through the DIP switches (see
HeadID)
USETESTDIP Use DIP switches 6, 7 or 8 for test mode acitvities.
Unit Bit 0 - activity of DIP switch 8 (tuning)
Bit 1 - activity of DIP switch 7 (test mode)
Bit 2 - activity of DIP switch 6 (type of test)
Bit 4 - tuning only allowed in test mode
Range 0 - 15
Default: 7