ATR60LF RFID Reader CAN Bus 7 Operation
Product Manual 7.4 Attribute (ECID and SVID) Values
CID_E99_PAD Customer has the possibility to look for padding information in MID in E99
mode. If CID_E99_PAD is set to ON the padding information will not be
filtered.
Default: OFF
CID_ERROR ON - returns an error if length of MID < CarrierIDLength
OFF - pads the MID as per the attributes CID_PAD and CID_JUSTIFY
Default: ON
CID_JUSTIFY R - MID is right-justified in MID space
L - MID is left-justified in MID space
Default: L
CID_MAX_LENGTH Takes value of (8 * N) where N = page 1 to 17
Default: 16
CID_NP_ASCII OFF - returns an error while reading/writing MID if MID contains non-
printable characters
ON - allows non-printable characters in MID while reading/writing MID
Default: OFF
CID_PAD ZERO - ASCII 0 (0x30) pads the MID
NUL - (0x00) pads the MID
Default: ZERO
Configuration (Read
only)
Number of connected heads (for Gateway). In case of reader only, the
value is always 01.
01 through 31
DeviceID Messages coming from the host will be replied with the same DeviceID as
sent from the host.
0x00 - 0xFF
Default: 0xFF
DeviceType (Read
only)
DeviceType is „CIDRW“.
DUAL_SENSOR At default value OFF only one sensor is defined and can be used to trigger
an automatic read.
The detection of sensor 1 will produce arrival event (S18F71) with MID of
the tag. The release of sensor 1 will produce removal event (S18F71)
without MID (zero length).
At value ON two sensors can trigger an automatic read. There is the
following behavior:
The detection of sensor 1 will produce arrival event (S18F71) with MID of
the tag. The external LED1 stays ON during read
(HOST_CONT_PORT1_LED=ON). The release of sensor 2 will produce