User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating Personnel
- 7.2 Theory of Operation
- 7.3 Data Items Dictionary
- 7.4 Attribute (ECID and SVID) Values
- AlarmStatus (Read only)
- ASCII_T1 (ASCII only)
- ASCII_T3 (ASCII only)
- BAUDRATE
- CarrierIDLength
- CarrierIDOffset
- CHECKSUM (ASCII only)
- CID_DISPLAY
- CID_E99_PAD
- CID_ERROR
- CID_JUSTIFY
- CID_MAX_LENGTH
- CID_NP_ASCII
- CID_PAD
- Configuration (Read only)
- DeviceID
- DeviceType (Read only)
- DUAL_SENSOR
- ENABLE_EVENTS
- ENABLE_TIMEOUTS (ASCII only)
- EXTENDEDSSACK
- HardwareRevision- Level
- HeadID
- HeadStatus
- HOST_CONT_PORT1 _LED
- HOSTNAME
- MANTWRITEONLY
- Manufacturer
- MDLN
- ModelNumber
- OperationalStatus
- PARITY
- PIP (Read only)
- PIP_AUTOREAD
- PIP_AUTOREAD_ DATA
- PIP_AUTOREAD_ LENGTH
- PIP_SENSOR_ POLARITY
- RADIO_RETRY
- RDA
- RW_ADJUSTMENT
- RW_REPEATTIME
- SELF_TEST_ RESULT
- SENSOR_TIMEOUT
- SERIALNUM
- SerialNumber
- SIGNALSTRENGTH (Read only)
- SW_PARTNUMBER
- SOFTREV
- SoftwareRevision- Level
- STATUS_ENABLE
- TARGETID
- USETESTDIP
- 7.5 Operation of the SECS Protocol
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
Brooks Automation
260301 Revision A 45
ATR60LF RFID Reader CAN Bus 7 Operation
Product Manual 7.4 Attribute (ECID and SVID) Values
Current values of status transitions with the corresponding attributes for
CIDRW and Head (if applicable). It has the following values:
1. “PMInformation” - Preventive maintenance information
“NE” = Normal execution
“MR” = Maintenance required
2. “AlarmStatus” - Current CIDRW sub-status of ALARM STATUS
“0” = NO ALARMS
“1” = ALARMS
3. “OperationalStatus” - Current CIDRW sub-status of OPERATIONAL
“IDLE”
“BUSY”
“MANT”
4. “HeadStatus” - The current status
“IDLE”
“BUSY”
“NOOP”
Subsystem ID, 2 bytes (SEMI E99-0200A, referred to as HeadID), e.g. 00,
01, 03, 10, 11, etc.
Identifies where a request for action or data is to be applied. It is zero for
the Gateway (RS485) and non-zero for the associated subsystem
components. It can only be set using the DIP switches on the subsystem.
Where used all stream 18 messages
7.4 Attribute (ECID and SVID) Values
AlarmStatus
(Read only)
Current CIDRW sub-status of ALARM STATUS
“0” = NO ALARMS
“1” = ALARMS
ASCII_T1
(ASCII only)
Inter-byte timeout
2 - 100 * 0.1 s (0.2 - 10 s)
Default: 100 (10 s)
STATUSn Format: 41
TARGETID Format: 41
IMPORTANT
Both 1 and 2 bytes are accepted as TargetID, but a response is always
two bytes.