User's Manual

Table Of Contents
Brooks Automation
44 260301 Revision A
7 Operation ATR60LF RFID Reader CAN Bus
7.3 Data Items Dictionary Product Manual
85 - Invalid ASCII command, ASCII protocol only
86 - Can not communicate to the target device; Link Manager only
87 - Invalid command structure, ASCII protocol only
88 - Invalid CarrierIDOffset, CarrierIDLength
89 - Non-printable ASCII character in MID
90 - 99 Not used
Where used S18F2, S18F4, S18F6, S18F8, S18F10, S18F12
Auto-ID subsystem commands
01 - 03: Not used
04: Switch LED on device
CPVAL <LEDStatus>
<Timeout>
<LEDNo>
05 - 06: Not used
07 or PerformDiagnostics
Self Test
08 - 12: Not used
13 or Reset: Reset unit (same effect as hardware power-up of unit)
14: Not used
15 or ChangeStatus:
Change the status from Maintenance to Operating and vice versa
CPVAL M or MT = Change to maintenance
O or OP = Change to operating
GetStatus
Get Status information
CPVAL IDLE or
MANT
LOCK
Lock specified page
CPVAL <PageNo>
DefaultParams
The parameters are set to default values.
The factory settings will not change.
ADJUST Starts an automatic adjustment process of the antenna.
DefParNoNetSet Parameters are set to default values. Only the
network settings will not be reseted.
Where used S18F13
The status of UP-STREAM CONTROLLER and its associated NODEs, 1 byte.
“1” - Component added to the bus
“2” - Component removed from the bus
Where used S18F71
SSCMD Format: 41
STATUS Format: 41