User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating Personnel
- 7.2 Theory of Operation
- 7.3 Data Items Dictionary
- 7.4 Attribute (ECID and SVID) Values
- AlarmStatus (Read only)
- ASCII_T1 (ASCII only)
- ASCII_T3 (ASCII only)
- BAUDRATE
- CarrierIDLength
- CarrierIDOffset
- CHECKSUM (ASCII only)
- CID_DISPLAY
- CID_E99_PAD
- CID_ERROR
- CID_JUSTIFY
- CID_MAX_LENGTH
- CID_NP_ASCII
- CID_PAD
- Configuration (Read only)
- DeviceID
- DeviceType (Read only)
- DUAL_SENSOR
- ENABLE_EVENTS
- ENABLE_TIMEOUTS (ASCII only)
- EXTENDEDSSACK
- HardwareRevision- Level
- HeadID
- HeadStatus
- HOST_CONT_PORT1 _LED
- HOSTNAME
- MANTWRITEONLY
- Manufacturer
- MDLN
- ModelNumber
- OperationalStatus
- PARITY
- PIP (Read only)
- PIP_AUTOREAD
- PIP_AUTOREAD_ DATA
- PIP_AUTOREAD_ LENGTH
- PIP_SENSOR_ POLARITY
- RADIO_RETRY
- RDA
- RW_ADJUSTMENT
- RW_REPEATTIME
- SELF_TEST_ RESULT
- SENSOR_TIMEOUT
- SERIALNUM
- SerialNumber
- SIGNALSTRENGTH (Read only)
- SW_PARTNUMBER
- SOFTREV
- SoftwareRevision- Level
- STATUS_ENABLE
- TARGETID
- USETESTDIP
- 7.5 Operation of the SECS Protocol
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
Brooks Automation
260301 Revision A 41
ATR60LF RFID Reader CAN Bus 7 Operation
Product Manual 7.3 Data Items Dictionary
Total bytes to be sent.
Range: 1 - 120
< DATASEG > must start with the first character "0" and be
followed by other numeric numbers. It indicates that the reading
will start from this offset up to the specified DATALENGTH.
Format code A9 is available on earlier versions of the software.
Please contact Brooks for availability of these format codes.
If DATALENGTH is present but DATASEG is not present, an error is
returned.
If both DATALENGTH and DATASEG have a length of zero, all data
is read.
To read/write pages, DATASEG ranges from "P1" - "P17" and DATA-
LENGTH ranges from 1 - 8.
Where used S18F5, F7
Used to identify the source of the requested data.
Range: 0 - 119
“0” and numeric offset: This is the byte offset (address) of the
start of specified data location to read from or write to.
If this field is zero length, DATASEG 00 is assumed.
To read/write pages, DATASEG ranges from “P1” - “P17” and DATA-
LENGTH ranges from 1 - 8.
Where used S18F5, S18F7
DATALENGTH Format: 41, A9
IMPORTANT
If the field has a length of zero, all the data from the DATASEG onwards
is reported.
DATASEG Format: 41