5 Product Specifications ATR60LF RFID Reader CAN Bus
5.3 Description of Components Product Manual
5.3 Description of Components
Components Description
RS232 interface The data are passed down serially to the RS232
interface (RJ45) with the different protocols. Baud
rates of 4,800 up to 57,600 Bd are possible.
Remote I/O The Remote I/O port is used for external presence
sensors and an external output like a LED for
status indication.
Power / CAN Bus
connection
Connector for power supply and CAN Bus
Antenna port Port for connecting an antenna
Reset button If the Reset button will be pressed a short time,
the communication parameters of the reader will
be reseted to default values. The network
settings, RS232, RS485, and protocol timer
parameters are involved. The CID parameters will
not be changed.
If the Reset button will be pressed longer than 5
seconds, the reader is restarted and all
parameters are set to default values.
DIP switches The DIP switches are used for setting the reader
address, test mode, protocol selection, switching
between reading and writing action in test mode
and for activation of automatic antenna tuning (
DIP Switches)
Power LEDs If the correct power supply is connected to the
device, the power LED lights up green and the
device is ready for operation.
Status LED The status LED indicates the current status of the
device.
Read / write ok
and Read / write
fail LED
The two Read / write LEDs indicate the result of
the last read or write action.