Performance Data Sheet

Circle Model RC100 System Performance Data Sheet
Brondell, Inc. P. O. Box 470085 San Francisco CA 94147-0085
888-542-3355 brondell.com support@brondell.com
Page 1 of 3
Rated Capacity 3,500 gal. for Aesthetic Chlorine / 243 gal. for VOC’s
Min-Max operating pressure: 40psi-120psi (275Kpa-827Kpa)
Min-Max feed water temperature: 41°F – 95°F (5°C – 35°C)
Rated Service Flow 0.07 gallons per minute
Daily Water Production Rate 56.9 gallons per day
Product Eciency Rating 30.6%
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the
system.
Refer to the owners manual for specic installation instructions, manufacturers limited warranty, user responsibility, and parts
and service availability.
The inuent water to the system shall include the following characteristics:
No organic solvents
Chlorine: < 2 mg/L
pH: 7 - 8
Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts.
The RC100 is tested and certied to NSF/ANSI 42, 53 and 58 for the reduction of Aesthetic Chlorine, Taste and
Odor, Cyst, VOCs, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium, Hexavalent Chromium,
Trivalent Chromium, Lead, Copper, Selenium and TDS as veried and substantiated by test data. The RC100
conforms to NSF/ANSI 372 for low lead compliance.
Substance
Inuent Challenge
Concentration
(mg/L unless specied)
Maximum Allowable Product Water
Concentration
(mg/L unless specied)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.05 +/- 10% 0.01 98.9
Barium 10.0 +/- 10% 2 98.2
Radium 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 +/- 10% 0.005 98.2
Chromium (Hexavalent) 0.3 +/- 10% 0.1 97.3
Chromium (Trivalent) 0.3 +/- 10% 0.1 97.8
Copper 3.0 +/- 10% 1.3 98.7
Lead 0.15 +/- 10% 0.01 98.2
Selenium 0.10 +/- 10% 0.05 97.3
Fluoride 8.0 +/- 10% 1.5 83.8
TDS 750 +/- 40 187 92.5
Aesthetic Chlorine 2.0 +/- 10 % >/= 50% Reduction 98.4
VOCs 0.300 +/- 10% >/= 95% Reduction 99.8
While testing was performed under laboratory conditions, actual performance may vary.
Iron: < 2 mg/L
Turbidity: < 1 NTU
Hardness: < 1 000 mg/L
This system has been tested according to NSF/ANSI 42, 53 and 58 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal
to the permissible for water leaving the system, as specied in NSF/ANSI 42, 53 and 58.

Summary of content (3 pages)