Operating instructions

23
Technical data (continuation)
Topas A8 Evolution with
lamp base Pulso G, Primo,
Unilite or Pulso Twin
Topas A8 Evolution with
Pulso lamp base 8
Flash energy 2 x 3050 J (4 x 1525 J) 6100 J
F-stop at distance of 2m 100
ISO, reflector P65
128 (Pulso Twin) 128
Flash duration t 0.1 (t 0.5) 3050J: 1/150s (1/600s) 6100J: 1/50s (1/230s)
with 230 V 1525J: 1/300s (1/1200s)
Charging time (for 100% of
selected energy)
0,5 – 5,2s 0,5 – 5,2s
Can be switched to low charge mode
Topas A8 Evolution is only designed for a mains voltage of 200 – 240 V.
Ready display Visual and audible (can be switched off), signals when 100% of selected
energy is reached
Lamp base outlets 4
Power output distribution Symmetrical and individual variable (asymmetrical)
Controls Dust and scratch proof, fully illuminated silicone keyboard and LED display.
Control range of flash energy 4 f-stops in 1/10 (1:16) intervals
can be switched to 5 f-stops (1:32).
By selecting the corresponding lamp outlet in asymmetrical mode additionally
1 f-stop
Maximum asymmetry 5 f-stops
Modelling light Halogen max. 4 x 650 W at 200-240 V
Proportional to flash energy and „full“ and „low“ settings. Proportionality
adjustable to other broncolor power packs and compact units and their various
output ranges.
Flash release Manual release button, photocell (can be switched off), infrared receiver (can
be switched off), sync cable, FCM 2, FCC, IRX2, IRQ
Release control Visual: Dim function of the modelling light, acoustic: buzzer
Additional function Sequences (flash series)
No. of sync. sockets 2
Stabilized flash voltage +/- 1%
Standards UL 122, EC-standards 73/23, 89/336 and 99/5
Power requirements 200-240 V / 50 Hz: 10 A
Dimensions (L x B x H) 280 x 162,7 x 446 mm
Weight kg 15,6
Subject to change in the interest of product enhancement.