Operating instructions

17
The LED array will blink “cell”-“ir”-“mod”-“test”-“sym” to indicate that you are in the
programming mode. In functions number 0 and 3, pressing the "up"/"down" key of the
digital display 1 (15) will toggle through the "prop", "dim" or "slow" green LED display in
order to show different parts of a multi-digit display.
Function number Meaning and possible settings
0 Program version ("prop" is lit)
Program number ("dim" is lit)
1 Setting ex works: off
„on“: Extended control range of the flash energy. The detailed
values are specified in section 3.1 of chapter 3. The lowest f-
stop level exhibits greater tolerances with regard to colour and
repetitive precision. The flash release is not guaranteed with all
lamp base types.
2
Switch on/ off the RFS Interface:
Settings ex works:”off”
“off”: RFS Interface is switched off
“on”: RFS Interface is switched on
3 Flash counter: "slow" is lit: xxxxXX
"dim" is lit: xxXXxx
"prop" is lit: XXxxxx
4 Delivery date: Month
5 Delivery date: Year
6 Country code
7
Setting the studio workstation:
By pressing the keys „up/down“ (17) of the digital display
number 1 (15) you can select the workstation („01“ to „10“).
You can select up to 10 studio workstations.
8
Setting the power pack address:
By pressing the keys „up/down“ (17) of the digital display
number 1 (15) you can select the desired power pack address
(„01“ to „10“). Per studio workstation you can select up to 10
different unit addresses.
Return to normal operation by pressing the "aux" key or by switching off and on again the unit.