TUNGSTEN SMART-HEAT™ WIRELESS ON/OFF CONTROL BY BROMIC USER MANUAL ! IMPORTANT Version 1.2 US Doc. T645.01 TVRCL916A02F6 READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL.KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE.
! IMPORTANT This manual contains important information about the installation, and operation of Tungsten Electric controller. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols: ! DANGER, ! WARNING, ! IMPORTANT • READ THIS MANUAL CAREFULLY before installing or servicing this product.
CONTENTS IMPORTANT NOTES & WARNINGS 4 PRODUCT OVERVIEW 5 INSTALLATION & OPERATION 6-8 TECHNICAL SPECIFICATIONS 8 TROUBLESHOOTING 8 WIRING DIAGRAM 9 www.bromicheating.
IMPORTANT NOTES AND WARNINGS ! WARNING • This appliance must only be used on a 110 - 230 Volt AC Single Phase electricity supply. • Read all instructions before installing or using this heater • • Use this controller only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. This controller is NOT intended to be installed on recreational vehicles and/or boats. • Do not run cord under carpeting.
PRODUCT OVERVIEW & INSTALLATION 1 DESCRIPTION The Wireless ON/OFF control is for resistive and infrared heaters. The controller allows the power output of the heater to be turned on/off, impulsive or timer controlled. The wireless control can be used with 110 - 230VAC supply voltages. 1.1 FEATURES • Controls TWO 3000W heaters at 230VAC (1500W at 110VAC). • Programmable relay functions: ON/OFF, impulsive and timer controlled up to 8hours, 59minutes and 59seconds. 1.
OPERATION 2.2.1 Setting relay function (on/off, impulse, timer) IMPULSE FUNCTION Press the ‘SET’ button once and hold it down until the ‘IMP’ LED turns on. Wait until the LED turns off to confirm the memorisation of the data. ON/OFF Function Press the ‘SET’ button twice and hold it down until the ‘ON-OFF’ LED turns on. Wait until the LED turns off to confirm the memorisation of the data. TIMER Function Setting the seconds (1 – 59) The starting value of the seconds is 1.
OPERATION Before starting select the output L1 or L2, using the switch (see picture at page 9). The following memorization/deletion will be applied only to the selected output. Anyway it’s possible to associate a double channel to both of the output, repeating the procedure. 2.2.2 Programming of a double channel 1. 2. Press the ‘MEM’ button two times and hold the button on the second time. There will be 2 beeps and followed by a continuous sound.
OPERATION 2.2.6 Deleting a remote from a remote. See remote manual for detail on P3 button. 1. 2. Press the P3 button inside the remote three times. There will be slow and intermittent sound. During the intermittent sound, press a button of the remote relative to the function to be deleted. The deletion is indicated by a continuous sound. 2.
WIRING DIAGRAM hours LED minutes LED Box opening seconds LED ON/OFF LED Impulsive LED Switch for output selection Out L1 ↑ Out L2 ↓ Aerial connection L N T T1 T2 Power EARTH supply (110/230Vac - 28A) L N L N OUT L1 OUT L2 (110/230Vac - 13A) (110/230Vac - 13A) 3000W max. at 230Vac 3000W max. at 230Vac 1500W max. at 110Vac 1500W max. at 110Vac Mount the product vertically with the cable glands downward L1 L2 N L LIVE NEUTRAL EARTH Power supply 110/230Vac L2 110/230Vac E 3000W max.