® Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03 Rev B
Copyright © 2009 - 2011 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
1 Introduction 1 Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2 Specifications 5 Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supplying power to the Mobility RFS7000 Controller . . . . . . . . . . . . . . . . . . . . . . . . 23 Verifying the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5 Regulatory Information 25 Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Laser Devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About This Document In this chapter • Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v • Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v • Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v • Contacting Brocade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi • Warranty coverage . . . . . .
Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data.
Downloads http://www.brocade.com/support/ Manuals http://www.brocade.com/support/ Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: documentation@brocade.com.
viii Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03
Chapter Introduction 1 In this chapter • Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 • Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 The Brocade Mobility RFS7000 Controller is a high-performance member of Brocade’s Wireless Controller family.
1 Warnings Warnings • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. • Remove jewelry and watches before installing this equipment. • Install the equipment in a rack with adequate dimensions and weight allowances. • Verify the rack is anchored and cannot tip over or break away from its mountings. • • • • • • Verify the unit is grounded before connecting it to the power source.
Site preparation 1 Site preparation • Consult your site survey and network analysis reports to determine specific equipment placement, port capacity, power drops, and so on. • • • • • • • Assign installation responsibility to the appropriate personnel. Identify where all installed components are located. Verify appropriate rack mounting requirements. Provide a sufficient number of power drops for your equipment. Ensure adequate, dust-free ventilation to all installed equipment.
1 4 Site preparation Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03
Chapter 2 Specifications In this chapter • Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 • Power cord specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Physical specifications Width 440mm (17.32 in) Height 44.45mm (1.75 in) Depth 390.8mm (15.38 in) Weight 6.12 Kg (13.
2 Power cord specifications • Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased.
Chapter 3 LED Codes In this chapter • System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 • RJ-45 Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 • SFP Gigabit Ethernet LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 • Out of band management port LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 System status LEDs Start up / post (primary system or redundant system) System status 1 LED System status 2 LED Event Off Off Power off Green blinking Green Blinking Power On Self Test (POST) running Green solid Green Blinking POST succeeded (Operating System Loading) Green solid Off POST succeeded (Normal Operation) Amber blinking Off POST Failure Alternating green blinking & amber blinking Alternating Green Blinking & Amber Blinking Boot Up Error: Device has an invalid checksum NO
3 System status LEDs Switch status (redundant system) System status 1 LED System status 2 LED Event Off Off Power off Green Solid Off No Redundancy Feature Enabled Green Blinking Green Solid Redundant System failed over and adopting ports Green Blinking Alternating Green Blinking & Amber Blinking Redundant System not failed over. Green Solid Amber Blinking No License to adopt Access Points or No Country Code configured on the switch.
3 RJ-45 Gigabit Ethernet LEDs Temperature status LED Temperature LED Event Off System Off Green Solid Ambient Inlet Temperature is within specified operating limit Amber Solid Ambient Inlet Temperature is near the maximum operating temperature During switch start up this LED will be lit Solid Amber. This is normal behavior and does not indicate an error.
3 SFP Gigabit Ethernet LEDs RJ-45 port speed LED Port speed LED Event Off 10 Mbps Green Solid 100 Mbps Green Blinking 1000 Mbps Amber Blinking Port Fault RJ-45 port status LED Port status LED Event Off No Link or Administratively shut down Green Solid Link present Green Blinking Activity: Transmit and Receive Amber Blinking Link Fault SFP Gigabit Ethernet LEDs Port Port speed status Upper Port sym_ Lower Port Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03 11
3 Out of band management port LEDs SFP port speed LED Port speed LED Event Green Blinking 1000 Mbps Amber Blinking Module or Tx/Rx Fault Loss SFP port status LED Port status LED Event Off No Link or Administratively shut down Green Solid Link present / Operational Amber Blinking Module or Tx/Rx Fault Loss Out of band management port LEDs Port speed Port status sym_0 12 Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03
Out of band management port LEDs 3 Out of band management port speed LED Port speed LED Event Off 10 Mbps Green Solid 100 Mbps Amber Blinking Port Fault Out of band management port status LED Port status LED Event Off No Link Green Solid Link present Green Blinking Activity: Transmit and Receive Amber Blinking Link Fault Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03 13
3 14 Out of band management port LEDs Brocade Mobility RFS7000 Controller Installation Guide 53-1001574-03
Chapter 4 Hardware Setup This chapter contains the following sections: • Cabling information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Gigabit Ethernet on the Mobility RFS7000 Controller . . . . . . . . . . . . . . . . . • Connecting USB devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Installing a compact flash card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Rack mount instructions . . . .
4 Cabling information Cabling information The Mobility RFS7000 Controller has four RJ-45 Gigabit Ethernet ports, four Gigabit SFP (fiber) ports, one Out-of-band management port and one Console connector. The diagram shows each of those ports and the cables or devices attached to them. The sections that follow describe detailed connection and cabling information for each port. For software configuration, please see the Mobility RFS7000 Controller System Reference Guide available from the Brocade website.
Gigabit Ethernet on the Mobility RFS7000 Controller 4 Gigabit Ethernet RJ45s Gigabit Ethernet SFPs Installing Gigabit Ethernet SFPs 1. Open the bail on the transceiver.
4 Gigabit Ethernet on the Mobility RFS7000 Controller 2. Insert each of the SFP transceivers into the corresponding ports on the switch. 3. Once the SFP transceivers are properly seated in their ports, close the bails to lock the transceivers in place. 4. Insert the fiber optic cables into the installed transceivers.
Connecting USB devices 4 Connecting USB devices USB ports The Mobility RFS7000 Controller contains two USB ports for connecting USB flash storage devices to the switch. The switch can use the USB flash storage devices for file transfers and firmware updates. Follow the setup instructions below to connect the devices to the switch and then access those devices through the Web UI or Command Line Interface. 1. Connect the USB flash drive to either of the USB ports. 2.
4 Installing a compact flash card NOTE The switch supports USB flash devices formatted with FAT or VFAT (FAT32) filesystems only. If your flash storage device is formatted with another filesystem you will need to format Installing a compact flash card Compact Flash slot Compact Flash The Mobility RFS7000 Controller contains a Compact Flash slot for file transfers, firmware updates and use by Brocade service technicians.
Rack mount instructions 4 Rack mount instructions To install the Mobility RFS7000 Controller in a rack: 1. The rack mounting brackets are installed at the factory. No additional steps are needed. 2. Attach the brackets to the rack using screws appropriate for your rack’s mounting holes.
4 Mobility RFS7000 Controller console port setup Mobility RFS7000 Controller console port setup To add the Mobility RFS7000 Controller to the network and prepare it for initial configuration: 1. Using the supplied console cable (pictured below), connect the Mobility RFS7000 Controller serial port to an RS-232 (DB-9) serial port on a separate computer (the “configuration computer”). 2.
Supplying power to the Mobility RFS7000 Controller 4 Supplying power to the Mobility RFS7000 Controller AC inlet Rack mount bracket sym_0 1. Plug an approved AC power cord into the power connector at the back of the Mobility RFS7000 Controller. 2. Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC. CAUTION An improper shutdown can render the Mobility RFS7000 Controller inoperable such that it could require service by Brocade Support.
4 Verifying the installation Verifying the installation View the LEDs on the front panel of the Mobility RFS7000 Controller to ensure the device is functioning properly. The normal LED pattern follows this path: • During the Power On Self Test (POST), the System 1 and System 2 LEDs both blink green. • If the POST test fails, the System 1 LED will blink amber. If the POST test succeeds, the System 1 LED will be lit solid green. • As the software is initialized, the System 2 LED will blink green.
Chapter Regulatory Information 5 In this chapter • Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Laser Devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . • Radio frequency interference requirements - FCC . . . . . . . . . . . . . . . . . . . • Radio frequency interference requirements - Canada . . . . . . . . . . . . . . . . • CE marking and European Economic Area (EEA) . . . . . . . . . . . . . . . . . . . .
5 Radio frequency interference requirements - FCC Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: CAUTION This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
CE marking and European Economic Area (EEA) 5 CE marking and European Economic Area (EEA) Statement of compliance Brocade hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC. A Declaration of Conformity may be obtained from http://www2symbol.
5 Waste Electrical and Electronic Equipment (WEEE) Japan power cord statement Chinese CCC statement Waste Electrical and Electronic Equipment (WEEE) For information on WEEE, please go to: http://www.brocade.com/company/corporate-citizenship/product-recycling/Overv iew/index.page.