Reference Guide (Supporting software release 5.5.0.0 and later) Owner manual
Brocade Mobility RFS Controller CLI Reference Guide 1005
53-1003098-01
14
storm-control [arp|broadcast|multicast|unicast] level <1-1000000> [fe <1-4>|
ge <1-8>|port-channel <1-8>|up1|wlan <WLAN-NAME>]
storm-control [arp|bcast|multicast|unicast] log
[<0-7>|alerts|critical|debugging|
emergencies|errors|informational|none|notifications|warnings]
Example
rfs7000-37FABE(config-fw-policy-test)#storm-control arp log warning
rfs7000-37FABE(config-fw-policy-test)#storm-control broadcast level 20000 ge 4
rfs7000-37FABE(config-fw-policy-test)#show context
firewall-policy test
ip dos fraggle drop-only
no ip dos tcp-sequence-past-window
ip dos tcp-max-incomplete high 600
arp Configures storm control for ARP packets
broadcast Configures storm control for broadcast packets
multicast Configures storm control for multicast packets
unicast Configures storm control for unicast packets
level <1-1000000> Configures the allowed number of packets received per second before storm control begins
• <1-1000000> – Sets the number of packets received per second
fe <1-4> Sets the FastEthernet port for storm control from 1 - 4
ge <1-8> Sets the GigabitEthernet port for storm control from 1 - 8
port-channel <1-8> Sets the port channel for storm control from 1- 8
up1 Sets the uplink interface
wlan <WLAN-NAME> Configures the WLAN
• <WLAN-NAME> – Sets the WLAN ID for the storm control configuration
arp Configures storm control for ARP packets
broadcast Configures storm control for broadcast packets
multicast Configures storm control for multicast packets
unicast Configures storm control for unicast packets
log Configures the storm control log level for storm control events
<0-7> Sets the numeric logging level from 0 - 7
alerts Numerical severity 1. Indicates a condition where immediate action is required
critical Numerical severity 2. Indicates a critical condition
debugging Numerical severity 7. Debugging messages
emergencies Numerical severity 0. System is unusable
errors Numerical severity 3. Indicates an error condition
informational Numerical severity 6. Indicates a informational condition
none Disables storm control logging
notification Numerical severity 5. Indicates a normal but significant condition
warnings Numerical severity 4. Indicates a warning condition. This is the default setting.