Owner's manual

System monitoring for Packet Processors
On FSX devices, errors typically detected in packet processors include:
Parity errors
Error Checking Code (ECC) errors
ConfigTable0 errors
TCAM error
TCAM action parity errors
Token bucket priority parity errors
State variable parity errors
Link list RAM ECC errors
FBUF RAM ECC errors
Egress VLAN parity errors
Ingress VLAN parity errors
Layer 2 port isolation parity errors
Layer 3 port isolation parity errors
VIDX parity errors
Besides the error count, sysmon also checks for connectivity of SFM/XBAR links. This happens at the
interval defined by the sysmon-timer command generally or specifically for cross bar.
Use the following commands to configure and display the statistics of cross bar or switch fabric
module:
sysmon pp error-count on page 310
show sysmon logs on page 312
show sysmon counters on page 313
show sysmon config on page 317
sysmon pp error-count
Configures the sysmon monitoring parameters for error events in packet processors. The no form of
this command resets the parameters to default values.
Syntax
sysmon pp error-count { threshold eventspolling-interval | log-backoff value | action { none |
syslog } }
no sysmon pp error-count
Parameters
threshold
Defines the failure threshold for the fabric adapter error-count event. The threshold is
defined as N/W, where N is the number of events, and W is the number of consecutive
polling periods. When the threshold is reached, actions configured for this event type will
take place. Note that a threshold of 1/W implies that there is no threshold, and no event will
be triggered.
log-backoff
If an error condition persists, it will be continuously logged (internally and/or externally). The
log back-off count skips configured number of logs before logging again. This avoids
overflow of the internal log or of the syslog.
action
System monitoring for Packet Processors
310 FastIron Ethernet Switch Administration Guide
53-1003075-02