Owner's manual
System Monitoring
● Supported system monitoring features......................................................................... 299
● Overview of system monitoring..................................................................................... 299
● Configure system monitoring........................................................................................ 300
● System monitoring on FCX and ICX devices................................................................ 303
● System monitoring for Fabric Adapters.........................................................................305
● System monitoring for Cross Bar.................................................................................. 307
● System monitoring for Packet Processors.................................................................... 310
Supported system monitoring features
Lists the system monitoring features supported on FastIron devices.
The table below lists the system monitoring (sysmon) features supported on Brocade FastIron devices.
These features are supported in the Layer 2 and full Layer 3 software images, except where explicitly
noted.
Feature ICX 6430 ICX 6450 FCX ICX 6610 ICX 6650 FSX 800
FSX 1600
ICX 7750
Fabric Adapter errors No No No No No 08.0.01 No
Packet Processor errors No No No No No 08.0.01 No
Cross Bar errors No No No No No 08.0.01 No
Link errors 08.0.01 08.0.01 08.0.01 08.0.01 No 08.0.01 No
Link InError detection 08.0.01 08.0.01 08.0.01 08.0.01 08.0.01 08.0.01 08.0.10
ECC errors 08.0.01 08.0.01 08.0.01 08.0.01 No 08.0.01 No
Sysmon enhancements No No No No No 08.0.01 No
Overview of system monitoring
System monitoring (sysmon) is a utility that runs as a background process and monitors connections
and components of the device for specific errors and logs them. It has a default policy that controls the
parameters that are monitored and actions to be taken if a fault is detected. These policies include the
type of errors, the threshold for errors to be logged, and the frequency of checking for errors. You can
use the CLI commands to configure these policies.
The sysmon utility monitors the hardware error registers to identify errors and failures. You can
configure the sysmon timer to define how frequently the sysmon utility queries the hardware error
registers. The data generated by the sysmon utility is written to either the sysmon internal log or to the
syslog.
FastIron Ethernet Switch Administration Guide
299
53-1003075-02