Owner's manual
U3-MSG: PoE Info: Resetting module in slot
1....completed.<======================================resetting twice===========
3. After downloading the firmware into the controller, the controller resets and reboot with the new PoE
firmware, You should see output similar to the following.
[MEMBER]local-3@ICX6450-24P Router>Download request from active unit 1 mac =
748e.f8dc.b39c
Downloading - poe.fw
Done.
PoE Info: Resetting in slot 1....
PoE Error: Device 0 failed to start on PoE module.<====================PoE Errors
on local console==========
PoE Error: Device 1 failed to start on PoE module.<===============PoE error
Resetting module in slot 1 again to recover from dev fault<=======Dev
fault=========
PoE Info: Hard Resetting in slot 1....<=====Hard reset=======
PoE Info: Programming Brocade defaults.....
PoE Info: Programming Brocade defaults. Step 1: Writing port defaults on module in
slot 1....
PoE Info: Programming Brocade Defaults: Step 2: Writing PM defaults on module in
slot 1.
PoE Info: Programming Brocade defaults. Step 3: Writing user byte 0xf0 on module
in slot 1.
PoE Info: Programming Brocade defaults. Step 4: Saving settings on module in slot
1.
PoE Info: Programming Brocade defaults....completed.
[MEMBER]local-3@ICX6450-24P Router>
NOTE
If you are attempting to transfer a file using TFTP but have received an error message, refer to
Firmware image file types.
Upgrading the PoE firmware file using SCP
To use the PoE feature, download the PoE firmware file. You can then install it using SCP as shown
below:
NOTE
In a stack, you must install the PoE firmware on each individual member unit.
1. Place the PoE firmware file on an SCP-enabled host to which the Brocade device has access.
2. Copy the PoE firmware file from the SCP-enabled host into the switch. To do so, enter the following
command on the SCP-enabled host:
For FCX and ICX 6610 devices:
pscp firmware hostname@management-ip:firmware:stackid:stack-id
For FSX devices:
pscp firmware hostname@management-ip:firmware:moduleid:module-id
For example:
C:/>pscp fsx_poe_07400.fw host1@10.10.1.1:firmware:stackid:1
The process of PoE firmware installation begins. On the FastIron device CLI, you should see the
output similar to the following:
Brocade(config)#scp download successful stackId = 1 file name = poe-fw
Sending PoE Firmware to Stack Unit 1.
PoE Warning: Upgrading firmware in slot 1....DO NOT SWITCH OVER OR POWER DOWN
THE UNIT.
PoE Info: FW Download on slot 1...sending download command...
PoE Info: FW Download on slot 1...TPE response received.
PoE Info: FW Download on slot 1...sending erase command...
Upgrading the PoE firmware file using SCP
FastIron Ethernet Switch Administration Guide 271
53-1003075-02