Owner's manual
Use the show media validation command to find out whether the connected optic modules are
supported or not on Brocade devices.
device# show media validation
Port Supported Vendor Type
-----------------------------------------------------------------------------
1/2/1 Yes FINISAR CORP. 1GE M-SX(SFP)
1/2/2 Yes BROCADE 10GE Twinax 1m (SFP +)
2/2/1 Yes BROCADE 10GE SR 300m (SFP +)
2/2/3 Yes BROCADE 10GE SR 300m (SFP +)
Syntax: show media [ validation [ ethernet [ unit / slot / port ] | slot slot-num | stack stack-id ] |
ethernet [ unit / slot / port ] | slot slot-num | stack stack-id ]
Viewing optical monitoring information
You can view temperature and power information for qualified XFPs, SFPs, and SFP+ installed in a
FastIron device.
Use the show optic command to view information about an XFP, SFP, or SFP+ installed in a
particular port. The following shows example output.
Optical monitoring feature will not work in the following scenarios:
• The port is DOWN.
• The port is configured as a stacking port.
• The the optic module does not support optical monitoring.
• For ICX 6430 devices only:
‐ If an SFP+ optic is inserted in an SFP only port, the optic will not initialize.
‐ If an SFP optic is inserted in an SFP+ only port, the optic will not initialize.
‐ If an optic is inserted into a device that supports both SFP and SFP+ optics, use the
speed-duplex command to set the port speed correctly.
device#show optic 13
Port Temperature Tx Power Rx Power Tx Bias Current
+----+-----------+----------+------------+-------------------+
13 33.2968 C -005.4075 dBm -007.4328 dBm 6.306 mA
Normal Normal Normal Normal
Syntax: showoptic port-number
Use the show optic slot on a FastIron X Series chassis to view information about all qualified XFPs,
SFPs, and SFP+ in a particular slot. The following shows example output.
device>show optic slot 4
Port Temperature Tx Power Rx Power Tx Bias Current
+----+-----------+----------+------------+-------------------+
4/1 30.8242 C -001.8822 dBm -002.5908 dBm 41.790 mA
Normal Normal Normal Normal
4/2 31.7070 C -001.4116 dBm -006.4092 dBm 41.976 mA
Normal Normal Normal Normal
4/3 30.1835 C -000.5794 dBm 0.000 mA
Normal Low-Alarm Normal Low-Alarm
4/4 0.0000 C 0.000 mA
Normal Normal Normal Normal
Syntax:show optic slot slot-number
NOTE
The show optic slot command is supported on the FSX 800 and FSX 1600 only.
Viewing optical monitoring information
214 FastIron Ethernet Switch Administration Guide