Owner's manual
Supported fiber optic transceivers (Continued)TABLE 28
Label Type Brocade part number Supports Digital
Optical Monitoring?
10G-XFP-ZR 10GBase-ZR XFP, 80 km 33014-000 Yes
10G-XFP-ZRD 10GBase-ZRD XFP, 80 km 33063-000 to 33107-000 Yes
10G-SFPP-SR 10GE SR SFP+ 57-0000075-01 Yes
10G-SFPP-LR 10GE LR SFP+ 57-0000076-01 Yes
10G-SFPP-TWX-0101 FCoE 1M Active Cable 58-1000026-01 No
10G-SFPP-TWX-0301 FCoE 3M Active Cable 58-1000027-01 No
10G-SFPP-TWX-0501 FCoE 5M Active Cable 58-1000023-01 No
10G-SFPP-ER 10GBase-ER SFP+, 40 km 57-0000085-01 Yes
10G-SFPP-LRM 10GBase-LRM SFP+ 57-0000084-01 Yes
E1MG-LHB 1000Base-LHB 33004-000 No
10G-SFPP-USR 10GE Ultra Short Reach (USR) SFP
+ 100m on OM3 MMF
57-1000130-01 Yes
40G-QSFP-C-0101 40GE QSFP Direct Attached Copper
Cable, 1m (stacking)
Used for stacking only.
58-0000033-01 No
40G-QSFP-C-0501 40GE QSFP Direct Attached Copper
Cable, 5m (stacking)
Used for stacking only.
58-0000035-01 No
Digital optical monitoring
You can configure your Brocade device to monitor optical transceivers in the system, either globally or
by specified ports. When this feature is enabled, the system will monitor the temperature and signal
power levels for the optical transceivers in the specified ports. Console messages and Syslog
messages are sent when optical operating conditions fall below or rise above the XFP, SFP, and SFP+
manufacturer recommended thresholds.
Digital optical monitoring configuration limitations
A Brocade chassis device can monitor a maximum of 24 SFPs and 12 XFPs.
Digital optical monitoring
FastIron Ethernet Switch Administration Guide 211
53-1003075-02