Administrator's Guide Supporting RSA Data Protection Manager (DPM) Environments (Supporting Fabric OS v7.2.0) Owner's manual
Table Of Contents
- Contents
- About This Document
- Encryption Overview
- In this chapter
- Host and LUN considerations
- Terminology
- The Brocade Encryption Switch
- The FS8-18 blade
- FIPS mode
- Performance licensing
- Recommendation for connectivity
- Usage limitations
- Brocade encryption solution overview
- Data encryption key life cycle management
- Master key management
- Support for virtual fabrics
- Cisco Fabric Connectivity support
- Configuring Encryption Using the Management Application
- In this chapter
- Encryption Center features
- Encryption user privileges
- Smart card usage
- Using authentication cards with a card reader
- Registering authentication cards from a card reader
- Registering authentication cards from the database
- Deregistering an authentication card
- Setting a quorum for authentication cards
- Using system cards
- Enabling or disabling the system card requirement
- Registering systems card from a card reader
- Deregistering system cards
- Using smart cards
- Tracking smart cards
- Editing smart cards
- Network connections
- Blade processor links
- Encryption node initialization and certificate generation
- Steps for connecting to a DPM appliance
- Exporting the KAC certificate signing request (CSR)
- Submitting the CSR to a certificate authority
- KAC certificate registration expiry
- Importing the signed KAC certificate
- Uploading the CA certificate onto the DPM appliance (and first-time configurations)
- Uploading the KAC certificate onto the DPM appliance (manual identity enrollment)
- DPM key vault high availability deployment
- Loading the CA certificate onto the encryption group leader
- Encryption preparation
- Creating an encryption group
- Adding a switch to an encryption group
- Replacing an encryption engine in an encryption group
- High availability clusters
- Configuring encryption storage targets
- Configuring hosts for encryption targets
- Adding target disk LUNs for encryption
- Adding target tape LUNs for encryption
- Moving targets
- Tape LUN write early and read ahead
- Tape LUN statistics
- Encryption engine rebalancing
- Master keys
- Security settings
- Zeroizing an encryption engine
- Using the Encryption Targets dialog box
- Redirection zones
- Disk device decommissioning
- Rekeying all disk LUNs manually
- Thin provisioned LUNs
- Viewing time left for auto rekey
- Viewing and editing switch encryption properties
- Viewing and editing encryption group properties
- Encryption-related acronyms in log messages
- Configuring Encryption Using the CLI
- In this chapter
- Overview
- Command validation checks
- Command RBAC permissions and AD types
- Cryptocfg Help command output
- Management LAN configuration
- Configuring cluster links
- Setting encryption node initialization
- Steps for connecting to a DPM appliance
- Initializing the Fabric OS encryption engines
- Exporting the KAC certificate signing request (CSR)
- Submitting the CSR to a CA
- Importing the signed KAC certificate
- Uploading the CA certificate onto the DPM appliance (and first-time configurations)
- Uploading the KAC certificate onto the DPM apliance (manual identity enrollment)
- Creating a Brocade encryption group
- Client registration for manual enrollment
- DPM key vault high availability deployment
- Setting heartbeat signaling values
- Adding a member node to an encryption group
- Generating and backing up the master key
- High availability clusters
- Re-exporting a master key
- Enabling the encryption engine
- Zoning considerations
- CryptoTarget container configuration
- Crypto LUN configuration
- Impact of tape LUN configuration changes
- Decommissioning LUNs
- Decommissioning replicated LUNs
- Force-enabling a decommissioned disk LUN for encryption
- Force-enabling a disabled disk LUN for encryption
- SRDF LUNs
- Using SRDF, TimeFinder and RecoverPoint with encryption
- Configuring LUNs for SRDF/TF or RP deployments
- SRDF/TF/RP manual rekeying procedures
- Tape pool configuration
- Configuring a multi-path Crypto LUN
- First-time encryption
- Thin provisioned LUNs
- Data rekeying
- Deployment Scenarios
- In this chapter
- Single encryption switch, two paths from host to target
- Single fabric deployment - HA cluster
- Single fabric deployment - DEK cluster
- Dual fabric deployment - HA and DEK cluster
- Multiple paths, one DEK cluster, and two HA clusters
- Multiple paths, DEK cluster, no HA cluster
- Deployment in Fibre Channel routed fabrics
- Deployment as part of an edge fabric
- Deployment with FCIP extension switches
- Data mirroring deployment
- VMware ESX server deployments
- Best Practices and Special Topics
- In this chapter
- Firmware upgrade and downgrade considerations
- Configuration upload and download considerations
- Configuration upload at an encryption group leader node
- Configuration upload at an encryption group member node
- Information not included in an upload
- Steps before configuration download
- Configuration download at the encryption group leader
- Configuration download at an encryption group member
- Steps after configuration download
- HP-UX considerations
- AIX considerations
- Enabling a disabled LUN
- Decommissioning in an EG containing mixed modes
- Decommissioning a multi-path LUN
- Disk metadata
- Tape metadata
- Tape data compression
- Tape pools
- Tape block zero handling
- Tape key expiry
- Configuring CryptoTarget containers and LUNs
- Redirection zones
- Deployment with Admin Domains (AD)
- Do not use DHCP for IP interfaces
- Ensure uniform licensing in HA clusters
- Tape library media changer considerations
- Turn off host-based encryption
- Avoid double encryption
- PID failover
- Turn off compression on extension switches
- Rekeying best practices and policies
- KAC certificate registration expiry
- Changing IP addresses in encryption groups
- Disabling the encryption engine
- Recommendations for Initiator Fan-Ins
- Best practices for host clusters in an encryption environment
- HA Cluster deployment considerations and best practices
- Key vault best practices
- Tape device LUN mapping
- Maintenance and Troubleshooting
- In this chapter
- Encryption group and HA cluster maintenance
- Displaying encryption group configuration or status information
- Removing a member node from an encryption group
- Deleting an encryption group
- Removing an HA cluster member
- Displaying the HA cluster configuration
- Replacing an HA cluster member
- Deleting an HA cluster member
- Performing a manual failback of an encryption engine
- Encryption group merge and split use cases
- A member node failed and is replaced
- A member node reboots and comes back up
- A member node lost connection to the group leader
- A member node lost connection to all other nodes in the encryption group
- Several member nodes split off from an encryption group
- Adjusting heartbeat signaling values
- EG split possibilities requiring manual recovery
- Configuration impact of encryption group split or node isolation
- Encryption group database manual operations
- Key vault diagnostics
- Measuring encryption performance
- General encryption troubleshooting
- Troubleshooting examples using the CLI
- Management application encryption wizard troubleshooting
- LUN policy troubleshooting
- Loss of encryption group leader after power outage
- MPIO and internal LUN states
- FS8-18 blade removal and replacement
- Brocade Encryption Switch removal and replacement
- Deregistering a DPM key vault
- Reclaiming the WWN base of a failed Brocade Encryption Switch
- Removing stale rekey information for a LUN
- Downgrading firmware from Fabric OS 7.1.0
- Fabric OS and DPM Compatibility Matrix
- Splitting an encryption group into two encryption groups
- Moving an encryption blade from one EG to another in the same fabric
- Moving an encryption switch from one EG to another in the same fabric
- State and Status Information
- Index

Fabric OS Encryption Administrator’s Guide (DPM) 271
53-1002922-01
General encryption troubleshooting
6
General encryption troubleshooting
Table 9 lists the commands you can use to check the health of your encryption setup. Table 10
provides additional information for failures you might encounter while configuring switches using
the CLI.
TABLE 9 General troubleshooting tips using the CLI
Command Activity
supportsave Check whole system configuration.
Run RAS logs.
Run RAS traces.
Run Security Processor (SP) logs (mainly kpd.log).
configshow Check whole system persistent configuration database dump.
Check for SPM-, CVLM-, and CNM-related persistent database entries.
cfgshow Check for redirection zones starting with “red_xxx” in defined database for
virtual and physical devices.
nsshow Check for crypto virtual target and crypto virtual initiator entries for VT/VI
switch:SecurityAdmin> cryptocfg --show
-groupcfg
Check key vault connection status.
Check encryption group/cluster status.
Note: CONVERGED status means the cluster is formed successfully.
switch:SecurityAdmin> cryptocfg --show
-groupmember -all
1 Check encryption group/cluster member status.
Note: DISCOVERED state means the member is currently part of a cluster.
2 Check encryption engine/SP and KEK status.
Note: SP state ONLINE means encryption engine is enabled for
encryption with valid KEK (Link Key or Master Key).
TABLE 10 General errors and conditions
Problem Resolution
Connection to a key vault returns a “Not Responding”
message.
Determine if the default port has been changed on the key vault.
After you create an encryption group using RKM/DPM, a
newly created container's LUN state changes between
“Write metadata is pending” and “Write metadata is in
progress” with continuous [RKD-1001] messages displayed
on the console.
Power cycle the DCX chassis and then issue the cryptocfg --enableEE [slot
number] command to bring the container’s LUN state to Encryption Enabled.If
the eth0 IP address on the Brocade Encryption Switch or on the FS8-18 port
blade has been modified, a reboot is required.
LUN state for some LUNS remains in "initialize" state on the
passive path.
This is expected behavior. The LUNs exposed through Passive paths of the
target array will be in either Initialize or LUN Discovery Complete state so long
as the paths remain in passive condition. When the passive path becomes
active, the LUN changes to Encryption Enabled. Use the --show -LUN
command with the -stat option to check the LUN state.