Administrator's Guide Supporting RSA Data Protection Manager (DPM) Environments (Supporting Fabric OS v7.2.0) Owner's manual
Table Of Contents
- Contents
- About This Document
- Encryption Overview
- In this chapter
- Host and LUN considerations
- Terminology
- The Brocade Encryption Switch
- The FS8-18 blade
- FIPS mode
- Performance licensing
- Recommendation for connectivity
- Usage limitations
- Brocade encryption solution overview
- Data encryption key life cycle management
- Master key management
- Support for virtual fabrics
- Cisco Fabric Connectivity support
- Configuring Encryption Using the Management Application
- In this chapter
- Encryption Center features
- Encryption user privileges
- Smart card usage
- Using authentication cards with a card reader
- Registering authentication cards from a card reader
- Registering authentication cards from the database
- Deregistering an authentication card
- Setting a quorum for authentication cards
- Using system cards
- Enabling or disabling the system card requirement
- Registering systems card from a card reader
- Deregistering system cards
- Using smart cards
- Tracking smart cards
- Editing smart cards
- Network connections
- Blade processor links
- Encryption node initialization and certificate generation
- Steps for connecting to a DPM appliance
- Exporting the KAC certificate signing request (CSR)
- Submitting the CSR to a certificate authority
- KAC certificate registration expiry
- Importing the signed KAC certificate
- Uploading the CA certificate onto the DPM appliance (and first-time configurations)
- Uploading the KAC certificate onto the DPM appliance (manual identity enrollment)
- DPM key vault high availability deployment
- Loading the CA certificate onto the encryption group leader
- Encryption preparation
- Creating an encryption group
- Adding a switch to an encryption group
- Replacing an encryption engine in an encryption group
- High availability clusters
- Configuring encryption storage targets
- Configuring hosts for encryption targets
- Adding target disk LUNs for encryption
- Adding target tape LUNs for encryption
- Moving targets
- Tape LUN write early and read ahead
- Tape LUN statistics
- Encryption engine rebalancing
- Master keys
- Security settings
- Zeroizing an encryption engine
- Using the Encryption Targets dialog box
- Redirection zones
- Disk device decommissioning
- Rekeying all disk LUNs manually
- Thin provisioned LUNs
- Viewing time left for auto rekey
- Viewing and editing switch encryption properties
- Viewing and editing encryption group properties
- Encryption-related acronyms in log messages
- Configuring Encryption Using the CLI
- In this chapter
- Overview
- Command validation checks
- Command RBAC permissions and AD types
- Cryptocfg Help command output
- Management LAN configuration
- Configuring cluster links
- Setting encryption node initialization
- Steps for connecting to a DPM appliance
- Initializing the Fabric OS encryption engines
- Exporting the KAC certificate signing request (CSR)
- Submitting the CSR to a CA
- Importing the signed KAC certificate
- Uploading the CA certificate onto the DPM appliance (and first-time configurations)
- Uploading the KAC certificate onto the DPM apliance (manual identity enrollment)
- Creating a Brocade encryption group
- Client registration for manual enrollment
- DPM key vault high availability deployment
- Setting heartbeat signaling values
- Adding a member node to an encryption group
- Generating and backing up the master key
- High availability clusters
- Re-exporting a master key
- Enabling the encryption engine
- Zoning considerations
- CryptoTarget container configuration
- Crypto LUN configuration
- Impact of tape LUN configuration changes
- Decommissioning LUNs
- Decommissioning replicated LUNs
- Force-enabling a decommissioned disk LUN for encryption
- Force-enabling a disabled disk LUN for encryption
- SRDF LUNs
- Using SRDF, TimeFinder and RecoverPoint with encryption
- Configuring LUNs for SRDF/TF or RP deployments
- SRDF/TF/RP manual rekeying procedures
- Tape pool configuration
- Configuring a multi-path Crypto LUN
- First-time encryption
- Thin provisioned LUNs
- Data rekeying
- Deployment Scenarios
- In this chapter
- Single encryption switch, two paths from host to target
- Single fabric deployment - HA cluster
- Single fabric deployment - DEK cluster
- Dual fabric deployment - HA and DEK cluster
- Multiple paths, one DEK cluster, and two HA clusters
- Multiple paths, DEK cluster, no HA cluster
- Deployment in Fibre Channel routed fabrics
- Deployment as part of an edge fabric
- Deployment with FCIP extension switches
- Data mirroring deployment
- VMware ESX server deployments
- Best Practices and Special Topics
- In this chapter
- Firmware upgrade and downgrade considerations
- Configuration upload and download considerations
- Configuration upload at an encryption group leader node
- Configuration upload at an encryption group member node
- Information not included in an upload
- Steps before configuration download
- Configuration download at the encryption group leader
- Configuration download at an encryption group member
- Steps after configuration download
- HP-UX considerations
- AIX considerations
- Enabling a disabled LUN
- Decommissioning in an EG containing mixed modes
- Decommissioning a multi-path LUN
- Disk metadata
- Tape metadata
- Tape data compression
- Tape pools
- Tape block zero handling
- Tape key expiry
- Configuring CryptoTarget containers and LUNs
- Redirection zones
- Deployment with Admin Domains (AD)
- Do not use DHCP for IP interfaces
- Ensure uniform licensing in HA clusters
- Tape library media changer considerations
- Turn off host-based encryption
- Avoid double encryption
- PID failover
- Turn off compression on extension switches
- Rekeying best practices and policies
- KAC certificate registration expiry
- Changing IP addresses in encryption groups
- Disabling the encryption engine
- Recommendations for Initiator Fan-Ins
- Best practices for host clusters in an encryption environment
- HA Cluster deployment considerations and best practices
- Key vault best practices
- Tape device LUN mapping
- Maintenance and Troubleshooting
- In this chapter
- Encryption group and HA cluster maintenance
- Displaying encryption group configuration or status information
- Removing a member node from an encryption group
- Deleting an encryption group
- Removing an HA cluster member
- Displaying the HA cluster configuration
- Replacing an HA cluster member
- Deleting an HA cluster member
- Performing a manual failback of an encryption engine
- Encryption group merge and split use cases
- A member node failed and is replaced
- A member node reboots and comes back up
- A member node lost connection to the group leader
- A member node lost connection to all other nodes in the encryption group
- Several member nodes split off from an encryption group
- Adjusting heartbeat signaling values
- EG split possibilities requiring manual recovery
- Configuration impact of encryption group split or node isolation
- Encryption group database manual operations
- Key vault diagnostics
- Measuring encryption performance
- General encryption troubleshooting
- Troubleshooting examples using the CLI
- Management application encryption wizard troubleshooting
- LUN policy troubleshooting
- Loss of encryption group leader after power outage
- MPIO and internal LUN states
- FS8-18 blade removal and replacement
- Brocade Encryption Switch removal and replacement
- Deregistering a DPM key vault
- Reclaiming the WWN base of a failed Brocade Encryption Switch
- Removing stale rekey information for a LUN
- Downgrading firmware from Fabric OS 7.1.0
- Fabric OS and DPM Compatibility Matrix
- Splitting an encryption group into two encryption groups
- Moving an encryption blade from one EG to another in the same fabric
- Moving an encryption switch from one EG to another in the same fabric
- State and Status Information
- Index
Fabric OS Encryption Administrator’s Guide (DPM) 157
53-1002922-01
Zoning considerations
3
No HA cluster membership
EE Attributes:
Media Type : DISK
EE Slot: 12
SP state: Online
Current Master KeyID:
a3:d7:57:c7:54:66:65:05:61:7a:35:2c:59:af:a5:dc
Alternate Master KeyID:
e9:e4:3a:f8:bc:4e:75:44:81:35:b8:90:d0:1f:6f:4d
HA Cluster Membership: hacDcx3
EE Attributes:
Media Type : DISK
Zoning considerations
When encryption is implemented, frames sent between a host and a target LUN are redirected to a
virtual target within an encryption switch or blade. Redirection zones are created to route these
frames. When redirection zones are in effect, direct access from host to target should not be
allowed to prevent data corruption.
Set zone hosts and targets together before configuring them for encryption. Redirection zones are
automatically created to redirect the host-target traffic through the encryption engine, but
redirection zones can only be created if the host and target are already zoned.
Setting default zoning to no access
Initially, default zoning for all Brocade Encryption Switches is set to All Access. The All Access
setting allows the Brocade Encryption Switch or DCX Backbone chassis to join the fabric and be
discovered before zoning is applied. If there is a difference in this setting within the fabric, the
fabric will segment.
Before committing an encryption configuration in a fabric, default zoning must be set to No Access
within the fabric. The No Access setting ensures that no two devices on the fabric can
communicate with one another without going through a regular zone or a redirection zone.
1. Check the default zoning setting. Commonly, it will be set to All Access.
switch:admin> defzone --show
Default Zone Access Mode
committed - All Access
transaction - No Transaction
2. From any configured primary FCS switch, change the default zoning setting to No Access.
switch:admin> defzone --noaccess
switch:admin> cfgfsave
The change will be applied within the entire fabric.