Reference (Supporting Fabric OS v7.3.0) Owner manual

Table Of Contents
Fabric OS Command Reference 535
53-1003131-01
islShow
2
To display interswitch links with D_Port enabled:
switch:user> islshow
1: 24->343 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:
16.000G CR_RECOV FEC
2: 25->341 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:
16.000G CR_RECOV FEC
3: 26-> 95 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:
16.000G CR_RECOV FEC
4: 27->340 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:
16.000G CR_RECOV FEC
5: 29->166 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:
16.000G CR_RECOV FEC
6: 30->165 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:
16.000G QOS CR_RECOV FEC
To display the neighbor switch WWN for the segmented ISLs during ELP and post ELP phase:
switch:user> islshow
[...]
1:9-> 2 10:00:00:05:1e:a3:00:59 (incompatible)
[...]
SEE ALSO switchShow, trunkShow