Table 2 lists the management specifications for the switch.
Certified maximum 6000 active nodes; combination of 56 switches, 19 hops; larger fabrics certified
as required.
ISL trunking Frame-based trunking with up to eight 8 Gbps ports per ISL trunk; up to 64 Gbps
per ISL trunk.
Aggregate bandwidth 512 Gbps per switch for non-encrypted traffic.
Maximum frame size 2112-byte payload for FC.
Classes of service Class 2 (non-encrypted traffic), Class 3, Class F (inter-switch frames).
Data traffic types Fabric switches supporting unicast, multicast (255 groups), and broadcast.
USB One USB port for system uploads and downloads, and firmware upgrades
(supportsave, configUploads, configDownloads).
Fabric services Simple Name Server (SNS), Registered State Change Notification (RSCN), NTP v3,
RCS (Reliable Commit Service), Dynamic Path Selection (DPS), Brocade Advance
Zoning (default zoning), Port/WWN zoning, broadcast zoning, NPIV, FDML,
Management Server, FSPF, Fabric Watch, Extended Fabrics, ISL Trunking,
Advanced Performance Monitoring (APM), Adaptive Networking, Per data flow QoS,
Ingress port rate limiting, Traffic Isolation, Group Management, Integrated Routing,
and IPFC.
TABLE 1 General specifications (Continued)
Specification Description
TABLE 2 Management specifications
Specification Description
Management Telnet, HTTP, LDAP, Syslog, SCP, Auditing, IP Filtering, SNMP v1/v3 (FE MIB, FC
Management MIB), Brocade Advanced WEB Tools, Brocade DCFM, SMI-S
compliant, SMI-S scripting toolkit.
Security and management SSL, SSH v2, HTTPS, RADIUS, RBAC (Role-Based Access Control), DH-CHAP
(between switches and end devices), port binding, switch binding, Secure RPC,
Trusted Switch, change tracking.
Management access Serial port (RJ-45) and one USB port. Call-home integration enabled through
DCFM.
Diagnostics and
supportability
POST and embedded online/offline diagnostics, including RAStrace logging,
environmental monitoring, non-disruptive daemon restart, RCping and Pathinfo (FC
traceroute), port mirroring (SPAN port), automatic trace dump transfers in support
of FFDC (first--failure data capture), supportsave utility.
Key management Compatible with industry-leading key management systems, including LKM
(NetApp/Decru) and RSA (EMC) Key Management Systems.