Hardware Reference Manual (Supporting Fabric OS v6.1.1_enc) User guide
Brocade Encryption Switch Hardware Reference Manual 27
53-1001117-02
3
Power supply
status
No light Indicates one of the following:
• Power supply FRU is switched
off.
• Power supply FRU is not seated
correctly.
• Power cord is disconnected.
• Power cord is not actively
powered.
• The power supply FRU has
failed.
Try the following:
• Verify that the power supply FRU
is powered on.
• Verify that the power supply FRU
is seated correctly.
• Check the power cable
connection.
• Replace the power supply FRU.
Steady green Power supply is operating normally. No action required.
Steady amber (for
more than 5
seconds)
Indicates one of the following:
• Power supply FRU is switched
off.
• Power supply FRU is not seated
correctly.
• The power cable is
disconnected.
• The power supply FRU has
failed.
Note: When the switch is first
powered on the power supply status
LED will show amber until POST has
completed.
Try the following:
• Verify that the power supply FRU
is powered on.
• Verify that the power supply FRU
is seated correctly.
• Check the power cable
connection.
• Replace the power supply FRU.
Fan status No light Indicates one of the following:
• Fan FRU is not seated correctly.
• Fan FRU is not receiving power.
Try the following:
• Verify that the fan FRU is seated
correctly.
• Verify that the switch is powered
on.
Steady green Fan assembly is operating normally. No action required.
Steady amber (for
more than 5
seconds)
Indicates one of the following:
• Fan FRU is not seated correctly.
• One or more of the fans in the
fan FRU has failed.
• The fan FRU was disabled by
the user.
Note: When the switch is first
powered on the fan status LED will
show amber until POST has
completed.
Try the following:
• Verify that the fan FRU is seated
correctly.
• Verify that the fan FRU is
enabled (use the fanEnable
command).
• Replace the fan FRU.
TABLE 2 Switch and FRU LEDs (Continued)
LED Name LED Color Status of Hardware Recommended Action