CFM Commands
Delay Measure Operations
ethernet cfm delay-measure binding
This command binds periodic delay-measure settings to a specified local MEP. Use the no form to
remove a binding.
Syntax
ethernet cfm delay-measure binding group group-index md domain-name ma ma-name
mpid mpid
no ethernet cfm delay-measure binding group md domain-name ma ma-name mpid mpid
group-index – Index for a group of delay-measure messages attributes. (Range: 1-200)
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
ma-name – Maintenance association name. (Range: 1-43 alphanumeric characters,
maximum length is 44 minus the length of the domain name)
mpid – Maintenance end point identifier. (Range: 1-8191)
Default Setting
None
Command Mode
Global Configuration
Command Usage
• If the specified attribute group has not been configured by the ethernet cfm delay-measure
group command, the binding will fail.
• If an attribute group is bound to any MEP, the attributes of group cannot be modified.
• To change the binding for a MEP, delay-measure messages must be disabled.
Example
This example shows an attribute group bound to a MEP.
Console(config)#ethernet cfm delay-measure binding group 1 md voip ma rd mpid 1
Console(config)#
TABLE 132 show fault-notify-generator - display description
Field Description
MD Name The maintenance domain for this entry.
MA Name The maintenance association for this entry.
Hihest Defect The highest defect that will generate a fault alarm. (This is disabled by default.)
Lowest Alarm The lowest defect that will generate a fault alarm (see the mep fault-notify
lowest-priority command).
Alarm Time The time a defect must exist before a fault alarm is issued (see the mep fault-notify
alarm-time, command).
Reset Time The time after a fault alarm has been issued, and no defect exists, before another
fault alarm can be issued (see the mep fault-notify reset-time command).