Configuration Guide (Supporting R2.2.0.0) Owner's manual

Brocade 6910 Ethernet Access Switch Configuration Guide 529
53-1002651-02
25
CFM Commands
ethernet cfm port-enable
This command enables CFM processing on an interface. Use the no form to disable CFM
processing on an interface.
Syntax
[no] ethernet cfm port-enable
Default Setting
Enabled
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
An interface must be enabled before a MEP can be created with the ethernet cfm mep
command.
If a MEP has been configured on an interface with the ethernet cfm mep command, it must
first be deleted before CFM can be disabled on that interface.
When CFM is disabled, hardware resources previously used for CFM processing on that
interface are released, and all CFM frames entering that interface are forwarded as normal
data traffic.
Example
This example enables CFM on port 1.
Console(config)#interface ethernet 1/1
Console(config-if)#ethernet cfm port-enable
Console(config-if)#
clear ethernet cfm ais mpid
This command clears AIS defect information for the specified MEP.
Syntax
clear ethernet cfm ais mpid mpid md domain-name ma ma-name
mpid – Maintenance end point identifier. (Range: 1-8191)
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
ma-name – Maintenance association name. (Range: 1-43 alphanumeric characters,
maximum length is 44 minus the length of the domain name)
Default Setting
None
Command Mode
Privileged Exec