Configuration Guide (Supporting R2.2.0.0) Owner's manual
1026 Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002651-02
43
Connectivity Fault Management
FIGURE 316 Transmitting Single-Ended Loss-Measure Messages
Displaying Local MEPs
Use the Administration > CFM > Show Information (Show Local MEP) page to show information for
the MEPs configured on this device.
CLI References
• “show ethernet cfm maintenance-points local” on page 532
• “show ethernet cfm maintenance-points local detail mep” on page 533
Parameters
These parameters are displayed:
• MEP ID – Maintenance end point identifier.
• MD Name – Maintenance domain name.
• Level – Authorized maintenance level for this domain.
• Direction – Direction in which the MEP communicates CFM messages:
• Down indicates that the MEP is facing away from the switch, and transmits CFM messages
towards, and receives them from, the direction of the physical medium.
• Up indicates that the MEP faces inward toward the switch cross-connect matrix, and
transmits CFM messages towards, and receives them from, the direction of the internal
bridge relay mechanism.
• Primary VLAN – Service VLAN ID.
• Interface – Physical interface of this entry (either a port or trunk).
• CC Status – Shows administrative status of CCMs.
• MAC Address – MAC address of this MEP entry.